Difference between revisions of "Manuals/Userful Network Video Wall/Network Zero Clients"
(Redirected page to Docs/Network Zero Clients) |
|||
(16 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | #REDIRECT [[Docs/Network Zero Clients]] | ||
+ | |||
{{ Public Support Wiki}} | {{ Public Support Wiki}} | ||
− | {{DISPLAYTITLE: Network Zero | + | {{DISPLAYTITLE: |
+ | Using Network Zero-Clients | ||
}} | }} | ||
{{CopyrightNotice|{{REVISIONYEAR}}}} | {{CopyrightNotice|{{REVISIONYEAR}}}} | ||
Line 39: | Line 42: | ||
==Introduction== | ==Introduction== | ||
− | Userful | + | Userful Network Video Wall™ enables you to group many displays to form a large display using one host PC/server. Userful's video wall solution is designed to use both the CPU and the GPU to maximize performance. |
+ | |||
+ | This document provides guidelines and instructions for configuring a video wall with Network Zero-Client Devices. | ||
== Compatible Devices == | == Compatible Devices == | ||
− | === Compatible Network Zero Client Devices === | + | === Compatible Network Zero-Client Devices === |
Userful Network Video Wall™ is designed to support network zero client devices (using the Elite Silicon® (EST) USB to LAN chipset) with the SMSC®chipsets. | Userful Network Video Wall™ is designed to support network zero client devices (using the Elite Silicon® (EST) USB to LAN chipset) with the SMSC®chipsets. | ||
Userful has tested and confirmed that the following devices are supported for use with Userful Network Video Wall™. | Userful has tested and confirmed that the following devices are supported for use with Userful Network Video Wall™. | ||
− | + | ||
+ | |||
{| {{prettytable}} | {| {{prettytable}} | ||
Line 59: | Line 65: | ||
|- | |- | ||
| align="center" |Atrust m320 ||align="center" | 039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | | align="center" |Atrust m320 ||align="center" | 039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | ||
+ | |- | ||
+ | | align="center" |Atrust m320(v2) ||align="center" | 116.103 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | ||
|- | |- | ||
| align="center" |Centerm C75 ||align="center" | 039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | | align="center" |Centerm C75 ||align="center" | 039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | ||
|- | |- | ||
− | | align="center" |HP T200 | + | | align="center" |HP T200 ||align="center" |035.226||align="center" |SMSC UFX-6000 ||align="center" |Yes |
|- | |- | ||
| align="center" |ViewSonic VMA-25 ||align="center" |039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | | align="center" |ViewSonic VMA-25 ||align="center" |039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | ||
Line 70: | Line 78: | ||
| align="center" |ViewSonic SC-U25 || align="center" |039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | | align="center" |ViewSonic SC-U25 || align="center" |039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | ||
|- | |- | ||
− | |align="center" |Centerm C75( | + | |align="center" |Centerm C75(v2) ||align="center" | 039.100 ||align="center" |SMSC UFX-6000 ||align="center" |Yes |
+ | |- | ||
+ | |align="center" | Atrust m321 ||align="center" | 116.103 ||align="center" |SMSC UFX-6000 ||align="center" |Yes | ||
|} | |} | ||
+ | |||
<br> | <br> | ||
{|{{Notes}} | {|{{Notes}} | ||
Line 82: | Line 93: | ||
==Getting Started== | ==Getting Started== | ||
− | Station setup should be done after installation of Userful Video Wall is complete. | + | Station setup should be done after the installation of the Userful Video Wall software is complete. |
Some things to remember: | Some things to remember: | ||
* Even when using network zero client stations, it is important to keep one station connected to the onboard video card in order to see startup messages. | * Even when using network zero client stations, it is important to keep one station connected to the onboard video card in order to see startup messages. | ||
* We recommend the use of homogeneous (all one type and model) network zero client devices. | * We recommend the use of homogeneous (all one type and model) network zero client devices. | ||
− | * '''Network zero client devices MUST be on the same subnet as the host PC to function.''' | + | * '''Network zero-client devices MUST be on the same subnet as the host PC/server to function.''' |
− | * If there is more than one host PC on a subnet, they '''must have unique hostnames'''. This is because network zero client devices are locked to host | + | * If there is more than one host PC/server on a subnet, they '''must have unique hostnames'''. This is because network zero-client devices are locked to host PC/servers based on the system name (or "hostname"). Having duplicate host names on one subnet cause erratic behaviour of the network devices. |
=== Setting Up Stations === | === Setting Up Stations === | ||
− | [[File: | + | [[File:Network_Station_Setup.png|thumb|right|600px|An example of a network station configuration.]] |
− | # Position one display to be plugged into the system tower; this is the '''onboard station'''. Input devices (keyboard and mouse) can be plugged directly into the system tower | + | # Position one display to be plugged into the system tower; this is the '''onboard station'''. Input devices (keyboard and mouse) can be plugged directly into the system tower (for either PS/2 or USB connections). |
# Connect one display to each zero-client device. | # Connect one display to each zero-client device. | ||
− | # Using Cat-5e network cable, connect each device to a gigabit-capable switch | + | # Using Cat-5e (or better) network cable, connect each device to a gigabit-capable switch. ''See example to the right''. |
− | # Connect the host PC to the switch | + | # Connect the host PC/server to the switch using Cat-5e (or better) network cable. |
# Ensure all devices, hubs and displays are connected to a UPS or surge protected outlets, if necessary. | # Ensure all devices, hubs and displays are connected to a UPS or surge protected outlets, if necessary. | ||
# Turn on the system when ready. | # Turn on the system when ready. | ||
<br clear="all"/> | <br clear="all"/> | ||
− | === Adding or Removing Network Zero Client Stations === | + | === Adding or Removing Network Zero-Client Stations === |
− | To add a station (assuming your license supports that number of stations), simply connect another device | + | To add a station (assuming your license supports that number of stations), simply connect another device. No reboot is necessary, the station will be ready to use after a brief pause.<br>'''Please note: it may take up to 60 seconds for the newly added station to be recognized by the host PC/server'''. No reboot is necessary. |
− | Stations can be removed simply by unplugging the device ( | + | Stations can be removed simply by unplugging the device (This can be done with the running system). |
+ | <br> | ||
+ | <br> | ||
+ | |||
+ | ==Zero-Client Configuration== | ||
+ | |||
+ | Zero-Client Configuration specifies how new zero-clients are assigned to host PC/server (i.e. automatic or manual assignment) by selecting: | ||
+ | * Automatically assign new zero-clients to this Host PC/Server, or | ||
+ | * Manually assign new zero-clients to this Host PC/Server | ||
+ | |||
+ | By default, administrators have to manually assign zero-client devices to the host PC/server. To assign zero-client stations, check [[Manuals/Userful_Multiplatform/Managing_Network_Zero_Client_Stations#Assigning_and_Releasing_Network_Stations |Assigning and Releasing Network Stations]] section. | ||
+ | <br><br> | ||
+ | |||
+ | ==Related Links== | ||
+ | |||
+ | * [[Manuals/Userful_Network_Video_Wall/Managing_Network_Zero_Client_Stations |Managing Network Zero-Client Stations]] | ||
+ | * [[Manuals/Userful Network Video Wall/Control Center |Control Center]] | ||
+ | |||
+ | <!-- | ||
== Firmware Updates for Network Zero Client Devices == | == Firmware Updates for Network Zero Client Devices == | ||
Line 117: | Line 146: | ||
To update firmware for all devices (recommended), click on the "Update All Firmware" radio button below the station list, then click apply. To update firmware for individual devices, click in the "Update Firmware" checkbox for each station that should have firmware updates applied, then click "Apply" to confirm the action. | To update firmware for all devices (recommended), click on the "Update All Firmware" radio button below the station list, then click apply. To update firmware for individual devices, click in the "Update Firmware" checkbox for each station that should have firmware updates applied, then click "Apply" to confirm the action. | ||
<br clear="all" /> | <br clear="all" /> | ||
+ | --> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | <!-- | ||
== Troubleshooting == | == Troubleshooting == | ||
Line 154: | Line 178: | ||
<li> Reset Userful VideoWall (through the Control Center > Help and Support > Troubleshoot > Reset Userful VideoWall).</li> | <li> Reset Userful VideoWall (through the Control Center > Help and Support > Troubleshoot > Reset Userful VideoWall).</li> | ||
</ol> | </ol> | ||
− | + | --> | |
{{forcewhitespace}} | {{forcewhitespace}} |
Latest revision as of 23:13, 19 February 2016
Redirect to:
Copyright © 2016 Userful Corporation. All rights reserved.
(Updated 2016.02.19)
To return to the Userful Network Video Wall main documentation page, Click Here.
Contents
Introduction
Userful Network Video Wall™ enables you to group many displays to form a large display using one host PC/server. Userful's video wall solution is designed to use both the CPU and the GPU to maximize performance.
This document provides guidelines and instructions for configuring a video wall with Network Zero-Client Devices.
Compatible Devices
Compatible Network Zero-Client Devices
Userful Network Video Wall™ is designed to support network zero client devices (using the Elite Silicon® (EST) USB to LAN chipset) with the SMSC®chipsets.
Userful has tested and confirmed that the following devices are supported for use with Userful Network Video Wall™.
Network Zero-Client Devices | Recommended Device Firmware | Graphics Chipset | External Power Supply Required |
Acer E400 | 039.100 | SMSC UFX-6000 | Yes |
Atrust m320 | 039.100 | SMSC UFX-6000 | Yes |
Atrust m320(v2) | 116.103 | SMSC UFX-6000 | Yes |
Centerm C75 | 039.100 | SMSC UFX-6000 | Yes |
HP T200 | 035.226 | SMSC UFX-6000 | Yes |
ViewSonic VMA-25 | 039.100 | SMSC UFX-6000 | Yes |
ThinNetworks MiniPoint Ethernet† | 039.100 | SMSC UFX-6000 | Yes |
ViewSonic SC-U25 | 039.100 | SMSC UFX-6000 | Yes |
Centerm C75(v2) | 039.100 | SMSC UFX-6000 | Yes |
Atrust m321 | 116.103 | SMSC UFX-6000 | Yes |
† Please Note that ThinNetworks MiniPoint devices are shipped with a jumper switch. The jumper switch toggles the device between an "always on" mode (ideal for digital signage and public computing environments) and a "normal" mode where power is controlled by power button. Please consult your sales representative for more information. |
Getting Started
Station setup should be done after the installation of the Userful Video Wall software is complete.
Some things to remember:
- Even when using network zero client stations, it is important to keep one station connected to the onboard video card in order to see startup messages.
- We recommend the use of homogeneous (all one type and model) network zero client devices.
- Network zero-client devices MUST be on the same subnet as the host PC/server to function.
- If there is more than one host PC/server on a subnet, they must have unique hostnames. This is because network zero-client devices are locked to host PC/servers based on the system name (or "hostname"). Having duplicate host names on one subnet cause erratic behaviour of the network devices.
Setting Up Stations
- Position one display to be plugged into the system tower; this is the onboard station. Input devices (keyboard and mouse) can be plugged directly into the system tower (for either PS/2 or USB connections).
- Connect one display to each zero-client device.
- Using Cat-5e (or better) network cable, connect each device to a gigabit-capable switch. See example to the right.
- Connect the host PC/server to the switch using Cat-5e (or better) network cable.
- Ensure all devices, hubs and displays are connected to a UPS or surge protected outlets, if necessary.
- Turn on the system when ready.
Adding or Removing Network Zero-Client Stations
To add a station (assuming your license supports that number of stations), simply connect another device. No reboot is necessary, the station will be ready to use after a brief pause.
Please note: it may take up to 60 seconds for the newly added station to be recognized by the host PC/server. No reboot is necessary.
Stations can be removed simply by unplugging the device (This can be done with the running system).
Zero-Client Configuration
Zero-Client Configuration specifies how new zero-clients are assigned to host PC/server (i.e. automatic or manual assignment) by selecting:
- Automatically assign new zero-clients to this Host PC/Server, or
- Manually assign new zero-clients to this Host PC/Server
By default, administrators have to manually assign zero-client devices to the host PC/server. To assign zero-client stations, check Assigning and Releasing Network Stations section.